E06
De Dietrich Control Board / Relay Fault

Dryer will not start or stops with E06; sometimes accompanied by unusual clicking from the control area.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed main control board, Stuck relay on PCB, Power surge damage to electronics, Corrupted control firmware

How to Fix / Troubleshooting

Safety first: Disconnect the appliance from mains before opening the control panel. Capacitors on the board can retain charge; avoid touching bare solder joints.

  • Power reset: Turn off the circuit breaker or unplug the dryer for at least 5 minutes. Reconnect and try to start a cycle. Transient faults may clear.
  • Check supply voltage: Verify that the wall outlet provides correct voltage and that there are no signs of intermittent power (flickering lights, tripping breaker).
  • Inspect control board: Remove the top cover and control panel fascia to access the main control board. Look for burnt components, cracked solder joints, or swollen capacitors.
  • Check connectors: Reseat all connectors to the board, especially those for power input, motor, heater, and user interface. Ensure no pins are bent.
  • Board replacement: If visual damage is present or E06 persists after checks, the control board is likely defective. Replace with the correct De Dietrich main PCB. Transfer any configuration jumpers as per service instructions. This repair is best done by a qualified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board