E18
Essentials
Heat Pump Compressor Fault
Dryer shows E18 and may not heat correctly on heat pump models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed heat pump compressor, Faulty compressor start relay, Low refrigerant charge (sealed system leak), Faulty compressor NTC sensor
How to Fix / Troubleshooting
Safety first: Unplug the dryer. Heat pump systems are sealed and contain refrigerant; only certified technicians should open the sealed system.
- Check basic airflow and filters: Before assuming a compressor fault, clean all filters, the condenser unit, and ensure good airflow around the dryer.
- Listen for compressor operation: During a cycle, you should hear the compressor start after a short delay. If it never starts or clicks repeatedly, there may be a compressor or start relay issue.
- Inspect compressor wiring: Access the compressor compartment and check that all connectors to the compressor and its start relay are secure and not burned.
- Do not attempt refrigerant repairs: If E18 persists and the compressor does not run or the unit does not heat, contact a qualified refrigeration technician. The heat pump module or compressor may need replacement and the system recharged.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Heat Pump Compressor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements