Fagor
Start Circuit / Safety Interlock Fault
Dryer powers on but will not start the cycle when Start/Pause is pressed; display remains on the program screen.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty door switch, Defective start button, Child lock function enabled, Failed main PCB input circuit
How to Fix / Troubleshooting
Safety first: Unplug the dryer before accessing the control panel or door switch.
- Check child lock: Refer to the user manual to see if a child lock icon is displayed. Disable the lock by holding the specified button combination.
- Verify door closure: Ensure the door is fully closed and latched. Inspect the door switch actuator and listen for a click when closing.
- Test door switch: Access the door switch from behind the front panel. Test for continuity when the door is closed. Replace if faulty.
- Inspect start button: Remove the control panel and test the start button or switch for continuity when pressed. Replace the button or UI board if defective.
- PCB input check: If switches are good, the main PCB input circuit may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Door Switch Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements