E11
Fagor Condenser Airflow / Heat Exchanger Blockage

Dryer displays E11; on condenser models, drying performance is poor and the unit may stop prematurely.

Advertisements

Possible Causes

Clogged condenser unit, Blocked condenser air channels, Heavy lint buildup in lower housing, Faulty condenser fan (on some heat pump models)

How to Fix / Troubleshooting

Safety first: Unplug the dryer. Condenser fins are sharp; handle with care.

  • Remove and clean condenser: Open the lower front flap and slide out the condenser (heat exchanger). Rinse thoroughly under running water to remove lint and dust. Allow it to drain and dry before reinstalling.
  • Clean housing: Use a vacuum and soft brush to clean the condenser compartment and air channels. Remove any lint mats blocking airflow.
  • Check condenser fan (if equipped): On heat pump models, access the fan behind the condenser. Ensure it spins freely and is not obstructed. Replace the fan motor if seized or noisy.
  • Reinstall correctly: Make sure the condenser is fully seated and the access door closes tightly to prevent air leaks.
  • Run a test cycle: After cleaning, run a full drying cycle and monitor for improved performance and absence of E11.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Unit (Heat Exchanger)
Check Price on Amazon