E11
Fagor
Condenser Airflow / Heat Exchanger Blockage
Dryer displays E11; on condenser models, drying performance is poor and the unit may stop prematurely.
Advertisements
Possible Causes
Clogged condenser unit, Blocked condenser air channels, Heavy lint buildup in lower housing, Faulty condenser fan (on some heat pump models)
How to Fix / Troubleshooting
Safety first: Unplug the dryer. Condenser fins are sharp; handle with care.
- Remove and clean condenser: Open the lower front flap and slide out the condenser (heat exchanger). Rinse thoroughly under running water to remove lint and dust. Allow it to drain and dry before reinstalling.
- Clean housing: Use a vacuum and soft brush to clean the condenser compartment and air channels. Remove any lint mats blocking airflow.
- Check condenser fan (if equipped): On heat pump models, access the fan behind the condenser. Ensure it spins freely and is not obstructed. Replace the fan motor if seized or noisy.
- Reinstall correctly: Make sure the condenser is fully seated and the access door closes tightly to prevent air leaks.
- Run a test cycle: After cleaning, run a full drying cycle and monitor for improved performance and absence of E11.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Unit (Heat Exchanger)
Check Price on Amazon
We may earn a commission from links on this page.