EF2
Frigidaire
Moisture sensor circuit fault or short
Frigidaire dryer shows EF2 and may stop or run erratically; sometimes associated with moisture sensor issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Contaminated moisture sensor bars, Shorted moisture sensor wiring, Failed moisture sensor assembly, Faulty main control board sensor input
How to Fix / Troubleshooting
Safety First: Unplug the dryer before working inside the drum or accessing wiring.
- Clean moisture sensor bars:
- Locate the two metal bars inside the drum near the lint filter opening.
- Clean them thoroughly with rubbing alcohol and a soft cloth to remove dryer sheet residue.
- Inspect wiring:
- Access the backside of the moisture sensor (usually behind the front panel).
- Check for pinched, broken, or shorted wires.
- Ensure connectors are firmly seated.
- Test sensor:
- Disconnect the sensor wires and check for continuity across the bars when bridged with a damp cloth; there should be a measurable resistance.
- Replace sensor or control:
- If the sensor is damaged or wiring is shorted, replace the moisture sensor assembly.
- If sensor and wiring are good but EF2 persists, the main control board may need replacement.