Frigidaire
User interface keypad failure
Frigidaire dryer display works but buttons are unresponsive or respond intermittently.
Advertisements
Possible Causes
Worn or damaged membrane switches, Moisture intrusion into console, Loose ribbon cable, Failed user interface board
How to Fix / Troubleshooting
Safety First: Unplug the dryer before removing the console.
- Power reset:
- Unplug for 5 minutes and reconnect to clear temporary glitches.
- Inspect console:
- Remove the top panel and console.
- Check the ribbon cable between UI and main board for secure connection.
- Check for moisture or corrosion:
- Look for signs of liquid spills or corrosion on the UI board.
- Replace UI board:
- If specific buttons consistently fail or the keypad is erratic, replace the user interface control board.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
User Interface Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements