Frigidaire User interface keypad failure

Frigidaire dryer display works but buttons are unresponsive or respond intermittently.

Advertisements

Possible Causes

Worn or damaged membrane switches, Moisture intrusion into console, Loose ribbon cable, Failed user interface board

How to Fix / Troubleshooting

Safety First: Unplug the dryer before removing the console.

  • Power reset:
    • Unplug for 5 minutes and reconnect to clear temporary glitches.
  • Inspect console:
    • Remove the top panel and console.
    • Check the ribbon cable between UI and main board for secure connection.
  • Check for moisture or corrosion:
    • Look for signs of liquid spills or corrosion on the UI board.
  • Replace UI board:
    • If specific buttons consistently fail or the keypad is erratic, replace the user interface control board.