E01
Gaggenau
Door lock / door switch fault
Dryer will not start; display shows E01 shortly after pressing Start.
Advertisements
Possible Causes
Defective door switch, Misaligned door latch, Broken door lock mechanism, Loose wiring at door switch harness
How to Fix / Troubleshooting
Safety first: Unplug the dryer or switch off the circuit breaker before any disassembly.
E01 on many Gaggenau dryers indicates the control does not see the door as properly closed.
- Check the door closure: Open and firmly close the door. Make sure no laundry is trapped in the door seal and that the latch engages with a clear click.
- Inspect the door latch and strike: Look at the metal or plastic strike on the cabinet and the latch on the door. If bent, cracked, or loose, tighten screws. Replace the latch or strike if damaged.
- Test the door switch: With power disconnected, remove the top or front panel (depending on model) to access the door switch. Disconnect the switch connector and test continuity with a multimeter while pressing the switch. If it does not change state (open/close), replace the door switch.
- Check wiring harness: Inspect the wiring from the door switch to the main control module for loose plugs, corrosion, or damaged insulation. Reseat connectors firmly.
- Reset power: After checks, restore power and try again. If E01 persists with a known-good switch and wiring, the main control board may be faulty and should be diagnosed by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch Assembly
Check Price on Amazon