E11
GE
Door Lock / Door Switch Circuit Error
GE dryer shows E11 and may not start or may shut off when the door is closed.
Advertisements
Possible Causes
Defective door switch, Loose door switch connector, Broken door strike, Faulty main control door input circuit
How to Fix / Troubleshooting
Safety first: Disconnect power before servicing.
Inspect door components:
- Check the door strike on the door; ensure it is not broken or bent. Replace if damaged.
- Open the door and locate the door switch. Press it manually; listen for a click.
- Remove the front panel or top panel to access the switch body.
- Disconnect the switch and test for continuity when pressed. Replace if it does not change state.
- Inspect the wiring harness from the switch to the main control board for damage or loose connections.
- Reassemble and test.
If the door switch and wiring are good but E11 remains, the main control board may need replacement.
Advertisements
Repair Difficulty
Easy
2/5