GE Faulty Push-to-Start Switch or Motor Relay Latch Circuit

GE dryer runs only when the Start button is held down and stops when released (mechanical timer models).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective push-to-start switch, Open motor run winding, Faulty motor centrifugal switch, Failed motor relay on control board

How to Fix / Troubleshooting

Safety first: Unplug the dryer.

Check push-to-start switch:

  • Access the console and locate the start switch.
  • Test the switch for continuity when pressed; replace if intermittent or open.

Check motor circuit:

  • If the start switch is good, the motor may not be latching due to a bad centrifugal switch or open run winding; replace the drive motor.
  • On electronic models with a motor relay, test and replace the relay or main control board if it does not hold the motor on.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Push-to-Start Switch
Check Price on Amazon