F5
Haier
Load Detection / Current Sensor Error
Haier dryer shows F5 and may not sense load or may end cycles too quickly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty current sensor on motor or heater circuit, Loose sensor wiring, Incorrect motor or heater replacement, Defective main control board
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing internal wiring and control boards.
- Inspect wiring to motor and heater: Check for loose or disconnected wires at the motor, heater, and any current sensor coils or modules.
- Verify correct parts: If the motor or heater was recently replaced, confirm that the correct Haier parts were installed and that wiring matches the service diagram.
- Check sensor module: Some models use a current transformer (CT) around a power lead. Ensure it is properly positioned and its connector is secure.
- Control board replacement: If wiring and sensors appear correct but F5 persists, the main control board may misread current and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Current Sensor Module
Check Price on Amazon