Hisense No Power / Control Board Not Energized

Dryer control panel is completely dead; no lights or response when pressing buttons.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on PCB, Faulty power filter board, Open thermal cutout in power circuit, Defective main control board

How to Fix / Troubleshooting

Safety first: Verify the outlet has power and unplug the dryer before opening panels.

  • Check outlet and breaker: Test the outlet with another appliance and ensure the breaker is not tripped.
  • Inspect power cord and terminal block: Confirm proper voltage at the terminal block inside the dryer.
  • Check internal fuse: On some Hisense models, the main PCB or power filter board has a replaceable fuse. Test and replace with the same rating if blown, but investigate the cause of the blow.
  • Inspect power filter board: Look for burnt components. Replace if damaged.
  • If power reaches the main PCB but the panel remains dead, the main control board is likely faulty and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Filter Board
Check Price on Amazon