F21
Hotpoint-Ariston Heat Pump Temperature / Pressure Sensor Fault

Heat pump dryer reports F21, poor drying performance, may stop with error mid-cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty high-pressure sensor, Faulty evaporator NTC sensor, Loose sensor wiring, Sensor out of range due to refrigerant issue

How to Fix / Troubleshooting

Safety first: Disconnect mains power before accessing internal components.

  • Clean heat exchanger: Ensure the evaporator and condenser surfaces are clean and not blocked by lint, as this can cause abnormal temperatures and pressures.
  • Locate sensors: Identify the NTC sensors on the heat pump circuit (evaporator and condenser) and any pressure sensor on the sealed system. Inspect wiring and connectors for damage or looseness.
  • Resistance check: Test NTC sensors for correct resistance at room temperature. Replace any that are open, shorted, or significantly out of specification.
  • Technician diagnosis: If sensors and wiring are good, a sealed system or pressure issue may be present. A qualified technician should check pressures and compressor performance.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heat Pump NTC Sensor / Pressure Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements