E15
Ikea Door Lock Circuit / Safety Interlock Error

Dryer displays E15, may not start or may stop unexpectedly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Intermittent door switch, Loose door lock wiring, Faulty door lock mechanism, Control board input fault

How to Fix / Troubleshooting

Safety first: Disconnect power before working on the door lock or wiring.

  • Inspect door and hinge: Ensure the door closes squarely and the hinge is not sagging. Adjust or tighten hinge screws if needed.
  • Check door lock assembly: Access the door lock from inside the front panel. Inspect for cracks, burnt smell, or loose connectors. Reseat the wiring plug.
  • Test door switch continuity: With a multimeter, verify that the switch changes state when the door is opened and closed. Replace the lock assembly if readings are inconsistent.

If the door lock tests good but E15 continues, the main control board may not be reading the signal correctly and may require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Lock Assembly