F09
Indesit EEPROM / Software Configuration Error

Indesit dryer shows F09, may behave erratically, wrong LEDs lit or programs not selectable

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM on main PCB, incorrect configuration data, failed main control board, power surge damage

How to Fix / Troubleshooting

Safety first: Unplug the dryer before accessing the control board.

Basic reset:

  • Disconnect power for at least 15 minutes to allow capacitors to discharge and the control to fully reset.
  • Reconnect and attempt to select a basic timed dry program. If F09 reappears, proceed to hardware checks.

Control board inspection:

  • Remove the top cover and access the main PCB.
  • Look for burn marks, swollen components, or corrosion. If present, the board should be replaced.
  • On some models, configuration jumpers or coding plugs must match the dryer model. Verify that any coding plug is correctly seated.

Resolution: F09 typically requires replacement of the main control board pre-programmed for the specific Indesit model. This is best handled by an authorized service center to ensure correct software and safety.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board (PCB)
Check Price on Amazon