JennAir Motor Run Circuit or Relay Failure

Dryer starts but stops when the Start button is released (only runs while holding the button).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed motor relay on control board, Open motor run winding, Faulty belt switch, Incorrect wiring after repair

How to Fix / Troubleshooting

Safety first: Unplug the dryer before testing internal components.

  • Check belt switch (if equipped): Ensure the drive belt is intact and properly tensioned over the idler. Test the belt switch for continuity when the belt is tight; replace if open.
  • Inspect motor connections: Verify all motor wires are firmly connected and not burned.
  • Test motor windings: With the dryer unplugged, measure resistance across the motor run winding terminals. An open reading indicates a failed motor.
  • Check motor relay: On electronic models, the control board uses a relay to keep the motor running. If the relay contacts are burned or the coil is open, the board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Drive Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements