F02
JennAir User Interface / Keypad Stuck or Shorted

Dryer displays F02 and may not respond to button presses or may behave erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck keypad button, Moisture or spill in console, Loose ribbon cable between UI and main control, Failed user interface board

How to Fix / Troubleshooting

Safety first: Unplug the dryer before removing the console or touching internal components.

  • Check for stuck buttons: Press each button on the control panel several times. If any button feels stuck or does not click, gently work it free. Wipe the panel with a slightly damp cloth and dry thoroughly.
  • Power reset: Leave the dryer unplugged for 5–10 minutes, then plug it back in and see if the code clears.
  • Inspect the console: Remove the console back cover. Locate the ribbon cable between the user interface (UI) and the main control board. Disconnect and reconnect the ribbon to clean the contacts.
  • Look for moisture or corrosion: If there are signs of liquid intrusion or corrosion on the UI board, the console assembly should be replaced.
  • Replace the user interface if needed: Transfer any knobs or trim, mount the new UI, reconnect the ribbon cable, reassemble the console, and test all buttons for proper response.