LG
Moisture Sensor Over-Reading / Stuck Wet
Dryer runs continuously and does not advance to end of cycle on sensor dry.
Advertisements
Possible Causes
Shorted moisture sensor bars, Sensor wires shorted to drum or chassis, Faulty main PCB sensor input
How to Fix / Troubleshooting
Safety first: Unplug dryer.
Steps:
- Inspect sensor bars: Ensure they are not bent and not touching each other or the drum.
- Check wiring: Inspect sensor harness for pinched or bare wires contacting metal.
- Replace sensor assembly: If no wiring faults are found, replace the moisture sensor assembly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Moisture Sensor Bars
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements