Possible Causes

Blocked blower wheel with lint or foreign objects, Worn or seized blower motor, Loose fan wheel on shaft, Wiring fault to blower motor

How to Fix / Troubleshooting

Safety first: Unplug the dryer. Sharp edges may be present inside the cabinet; wear gloves.

  • Access blower housing: Remove the rear or side panel to reach the blower assembly connected to the air duct.
  • Inspect blower wheel: Check for lint clumps, socks, or other items lodged in the wheel. Remove any obstructions carefully.
  • Check fan rotation: Spin the blower wheel by hand. It should turn freely without wobble. Replace if cracked or loose on the shaft.
  • Test blower motor: Verify that the blower motor receives power during operation (only if you are competent and can do so safely). If powered but not turning, the motor is likely faulty.
  • Replace components as needed: Install a new blower motor or fan wheel if defective, reassemble ducts, and test airflow.