Logik
Faulty Control Panel Keypad
Dryer display works but some buttons do not respond or respond intermittently
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn or damaged membrane switches, Moisture ingress behind fascia, Loose ribbon cable to control PCB
How to Fix / Troubleshooting
Safety first: Unplug the dryer before removing the control panel.
- Power reset: Unplug the dryer for 5–10 minutes, then reconnect and test the buttons again.
- Access control panel: Remove the top cover and screws securing the fascia. Carefully pull the panel forward.
- Check ribbon cable: Ensure the flat cable between the keypad and main PCB is fully seated and not damaged.
- Inspect for moisture: Look for signs of condensation or spills behind the panel. Dry gently with a lint-free cloth.
- Replace control panel: If specific buttons remain unresponsive, the keypad or UI PCB will likely need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel PCB
Check Price on Amazon