tO
Maytag Thermistor Open (Samsung-style code on some Maytag models)

Dryer displays tO and may not heat correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open exhaust thermistor, Broken thermistor wiring, Unplugged thermistor connector, Overheated and failed thermistor

How to Fix / Troubleshooting

Safety First: Disconnect power before servicing.

  • Step 1 – Inspect thermistor connector: Ensure the connector is fully seated on the thermistor terminals.
  • Step 2 – Test thermistor: Disconnect and measure resistance at room temperature. Infinite resistance indicates an open thermistor that must be replaced.
  • Step 3 – Replace thermistor: Remove mounting screw(s), install a new OEM thermistor, and reconnect wiring.
  • Step 4 – Check for overheating causes: Clean lint from the blower housing and vent system to prevent future overheating.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Exhaust Thermistor
Check Price on Amazon

We may earn a commission from links on this page.