F56
Miele Inlet Air Temperature Too Low / Ambient Condition Fault

Dryer shows F56 and may not heat effectively.

Advertisements

Possible Causes

Dryer installed in very cold room, faulty inlet NTC sensor, control misreading ambient temperature

How to Fix / Troubleshooting

Safety first: Unplug the dryer before internal checks.

Correct ambient and sensor issues:

  • Ensure the dryer is installed in a room within the manufacturer’s recommended temperature range (typically above 10°C).
  • Check that air inlets are not blocked and that the room is not subject to strong drafts.
  • Test the inlet NTC sensor for correct resistance at room temperature; replace if out of specification.
  • If the environment and sensor are correct but F56 persists, the control board may require professional diagnosis.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Inlet NTC Sensor
Check Price on Amazon