Monogram
Overheating Motor or Thermal Protection Trip
Dryer shuts off after a few minutes and will restart after cooling down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failing drive motor overheating, Restricted airflow causing high internal temperatures, Blocked blower wheel, Worn drum support components increasing load
How to Fix / Troubleshooting
Safety first: Unplug the dryer before inspection. Components may be hot; allow cooling time.
- Clean airflow path: Ensure the lint filter, internal ducts, and external vent are clean and unobstructed.
- Check drum movement: Rotate the drum by hand to ensure it turns freely. Repair or replace worn rollers, glides, or idler pulley.
- Inspect blower: Check the blower wheel for obstructions and ensure it spins freely.
- Motor evaluation: If mechanical parts are free and airflow is good, but the dryer still shuts down and restarts after cooling, the drive motor may be overheating internally and should be replaced.