E18
Monogram
Exhaust Temperature Too Low / Vent Sensor Error
Dryer displays E18, drum turns but no heat, often after long vent runs
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Very long or oversized vent run, Cold ambient temperature, Faulty exhaust thermistor reading low, Control board misinterpretation of exhaust temp
How to Fix / Troubleshooting
Safety first: Unplug the dryer before accessing internal components.
- Evaluate vent design: Check that the vent run length and number of elbows meet Monogram specifications. Excessive length or elbows can cause low exhaust temperatures and poor drying.
- Inspect vent for leaks: Ensure all vent joints are sealed and that there are no disconnected sections allowing heat to escape into the home.
- Test exhaust thermistor: Access the exhaust thermistor on the blower housing and test its resistance at room temperature. Replace if out of specification.
- Control check: If venting and thermistor are correct, the main control board may be misreading the sensor and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Exhaust Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements