E05
Montpellier
Motor Drive Fault
Dryer shows E05 and drum does not rotate; you may hear a relay click but no drum movement.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed drum drive motor, Worn or broken drive belt, Faulty motor capacitor (on capacitor-start motors)
How to Fix / Troubleshooting
Safety first: Disconnect mains power. Moving parts can cause injury; keep hands clear when testing.
- Check drum movement: Open the door and try to rotate the drum by hand. It should turn smoothly with moderate resistance. If it is jammed, inspect for foreign objects between drum and cabinet.
- Listen for motor hum: Start a cycle with the door closed. If you hear a humming noise but no rotation, the belt may be broken or the capacitor/motor is faulty.
- Inspect the belt: Remove the top and rear panel. Check if the belt is intact and correctly routed around the motor pulley and idler pulley. Replace if frayed or snapped.
- Check motor capacitor: Locate the motor start capacitor (usually near the motor). Look for bulging, leaks, or burn marks. A faulty capacitor should be replaced with the exact µF rating specified for the Montpellier model.
- Test run: After replacing belt or capacitor, reassemble and test. If E05 persists and the motor does not run, the motor windings or control board triac/relay may be defective and require professional diagnosis.