Proline
Door Switch or Drum Light Circuit Fault
Dryer drum light stays on even when the door is closed, or never comes on at all.
Advertisements
Possible Causes
Stuck door switch, Failed drum light bulb or LED, Broken wire to door switch
How to Fix / Troubleshooting
Safety first: Unplug the dryer before accessing the door switch or light assembly.
Step-by-step checks:
- Test door switch: Press the door switch plunger by hand with the door open. If the light does not change state, the switch may be faulty.
- Replace bulb (if fitted): On models with a replaceable bulb, remove the lens cover and fit a new bulb of the correct type.
- Check wiring: Access the switch from behind the front panel and inspect the wiring for breaks or loose connectors.
When to call a technician: If the light is LED-integrated or controlled directly by the PCB, board-level diagnosis may be needed.