Proline Door Switch or Drum Light Circuit Fault

Dryer drum light stays on even when the door is closed, or never comes on at all.

Advertisements

Possible Causes

Stuck door switch, Failed drum light bulb or LED, Broken wire to door switch

How to Fix / Troubleshooting

Safety first: Unplug the dryer before accessing the door switch or light assembly.

Step-by-step checks:

  • Test door switch: Press the door switch plunger by hand with the door open. If the light does not change state, the switch may be faulty.
  • Replace bulb (if fitted): On models with a replaceable bulb, remove the lens cover and fit a new bulb of the correct type.
  • Check wiring: Access the switch from behind the front panel and inspect the wiring for breaks or loose connectors.

When to call a technician: If the light is LED-integrated or controlled directly by the PCB, board-level diagnosis may be needed.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.