E19
Rangemaster Configuration / EEPROM Fault

Dryer displays E19; may occur immediately after power-up; no other functions available.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted configuration data on main PCB, Incompatible replacement control board, Failed EEPROM memory chip, Interrupted firmware update (if applicable)

How to Fix / Troubleshooting

Safety first: Disconnect the dryer from the mains before accessing the control board.

  • Power cycle: Unplug the dryer for at least 10 minutes, then reconnect to see if the error clears.
  • Check model configuration: If the main PCB was recently replaced, verify that the correct Rangemaster part number was installed and that any required configuration procedure was completed according to the service manual.
  • Inspect control board: Remove the top cover and inspect the main PCB for physical damage or signs of overheating.
  • Reprogramming (service only): Some boards can be reprogrammed with the correct configuration using manufacturer tools. This typically requires an authorised service technician.
  • Replace main PCB: If configuration cannot be restored and E19 persists, replace the main control PCB with the correct, pre-configured Rangemaster part.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements