Possible Causes

Mechanical jam in door lock, Swollen or misaligned door seal, Faulty door lock mechanism, Control not releasing lock

How to Fix / Troubleshooting

Safety first: Switch off and unplug the dryer. Do not force the door open with excessive strength.

  • Wait a few minutes: Some Siemens dryers keep the door locked briefly after cycle end. Wait 2–5 minutes and try again.
  • Check for obstruction: Gently press on the door while pulling the handle to relieve pressure from the latch. Ensure no clothing is trapped in the door area.
  • Manual release: Many models have a manual door lock release accessible through the pump or filter flap. Consult the user manual and pull the emergency release tab if provided.
  • Inspect lock: Once open and unplugged, remove the front panel or door seal clamp to access the lock. Replace the door lock assembly if it is mechanically damaged or burnt.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Lock Assembly