E10
Siemens
Mains Voltage / Power Supply Fault
Dryer displays E10 and may not start or may stop unexpectedly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect supply voltage, Loose mains terminal block connection, Faulty mains filter (EMI filter), Internal power supply failure on control board
How to Fix / Troubleshooting
Safety first: Turn off the circuit breaker and verify the dryer is de-energized before opening the terminal cover.
- Verify supply voltage: Ensure the dryer is connected to the correct voltage as specified on the Siemens rating plate. Use a multimeter to confirm stable voltage at the outlet.
- Inspect mains cable and plug: Check for damage, overheating, or discoloration. Replace a damaged cable or plug immediately.
- Check terminal block: Open the rear terminal cover and inspect the connection screws. Tighten any loose terminals and look for signs of arcing or melting.
- Examine mains filter: The EMI filter is usually near the mains entry. Look for bulging capacitors or burnt components. Replace the filter if damaged.
- Control board power section: If external wiring is sound, the internal low-voltage power supply on the control board may be defective. Replacement of the control module is typically required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Mains Filter / Interference Suppression Filter
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements