E10
SMEG Fan Motor / Blower Fault

Dryer shows E10 and stops; on condenser/heat pump models, there may be little or no airflow.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed blower fan motor, Obstructed blower wheel with lint or foreign object, Broken blower wheel hub, Faulty fan motor capacitor (if separate)

How to Fix / Troubleshooting

Safety first: Disconnect the dryer from mains power. Moving fan blades can cause injury; never work on the blower with power connected.

  • Check airflow: With the dryer running (before disconnecting), feel at the exhaust or front outlet for airflow. Weak or no airflow suggests a blower issue.
  • Access blower assembly: Remove the rear or front lower panel (model-dependent) to reach the blower housing.
  • Inspect blower wheel: Look for lint clumps, socks, or other objects jammed in the blower. Remove any obstructions carefully.
  • Check blower wheel attachment: Ensure the wheel is firmly attached to the motor shaft. If the hub is cracked or the wheel spins freely on the shaft, replace the blower wheel.
  • Test fan motor: Disconnect the motor and measure winding resistance. If open or shorted, replace the fan motor. If a separate capacitor is used, test and replace if out of specification.
  • Reassemble and test: After clearing obstructions or replacing parts, reassemble panels and run a test cycle to confirm normal airflow and that E10 is cleared.