E18
Stoves Low Voltage / Power Fluctuation Detection

Dryer displays E18 and the drum light flickers or the display dims intermittently

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Undersized supply wiring, Loose power cord plug, Failing house breaker, Internal wiring harness loose connection

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before inspecting power connections.

  • Check outlet and plug: Ensure the dryer plug is fully inserted and not hot to the touch. A warm plug indicates a poor connection.
  • Inspect terminal block: Remove the rear cover and check for loose or burnt connections at the terminal block. Tighten and replace damaged parts as needed.
  • Verify house wiring: If possible, have a qualified electrician check the circuit for proper wire gauge and secure connections at the breaker panel.
  • Internal harness check: Inspect the main power harness inside the dryer for loose connectors or damaged insulation. Reseat connectors on the control board and filter board (if present).
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Power Cord and Terminal Block
Check Price on Amazon

We may earn a commission from links on this page.