Whirlpool
No Incoming Power or Open Thermal Fuse
Dryer will not power on at all; no lights or display
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped breaker, Unplugged or faulty power cord, Open thermal fuse, Failed main control board (less common)
How to Fix / Troubleshooting
Safety First: Turn off the breaker before inspecting the terminal block. 240 VAC is hazardous.
- Check power source: Verify the dryer is plugged in and the breaker is on. Test the outlet with another appliance or a multimeter.
- Inspect power cord and terminal block: Remove the rear cover and check for loose or burnt connections. Replace damaged cords or terminal blocks.
- Test thermal fuse: Unplug the dryer, locate the thermal fuse on the blower housing, and test for continuity. Replace if open and correct any airflow issues.
- Control board: If power is present at the terminal block and thermal fuse is good but the dryer is still dead, the main control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5