Bradley Smoker
No Power to Control Box
Display is completely dead; smoker does not power on at all.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown internal fuse, Faulty power cord, Loose power inlet connection, Failed control board power supply
How to Fix / Troubleshooting
Safety first: Unplug the smoker before opening the control box. If you are not comfortable working with mains wiring, seek professional help.
Diagnostic steps:
- Verify outlet: Test the wall outlet with another appliance to confirm it has power.
- Inspect power cord: Check for visible damage. Wiggle the cord gently at both ends while watching for any flicker (if the display briefly lights, the cord or inlet may be loose).
- Check internal fuse: Open the control box and look for a small fuse on the board or inline with the power input. Test it with a multimeter and replace with the same rating if blown.
- Inspect power inlet: Ensure the power inlet socket on the control box is firmly mounted and its solder joints are intact.
- Replace control box: If the fuse and cord are good but there is still no power, the internal power supply on the control board has likely failed. Replace the digital control box.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Power Cord / Digital Control Box
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements