E3
Bradley Smoker
Control Board Temperature Calibration / Sensor Range Error
Digital Bradley smoker display shows E3 and heating element does not cycle correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect sensor type or wiring, Control board firmware fault, Damaged control board temperature input circuit, Poor connection between sensor and control board
How to Fix / Troubleshooting
Safety first: Unplug the smoker before opening the control box or accessing wiring.
Steps to troubleshoot E3:
- Verify correct sensor: Ensure the installed temperature sensor is the correct Bradley RTD probe for your model. Using a non‑OEM or wrong type sensor can cause range errors.
- Check all sensor connections: Remove the control box, locate the sensor connector on the board, and ensure it is fully seated with no bent pins or corrosion.
- Inspect wiring harness: Follow the harness from the sensor to the control board. Look for splices, damage, or signs of overheating. Repair or replace the harness if needed.
- Power reset: With everything reconnected, plug the smoker back in and perform a full power reset (unplug for 5–10 minutes, then reconnect) to clear transient faults.
- Replace control box: If E3 persists with a known‑good sensor and wiring, the control board is likely defective. Replace the complete Bradley digital control box assembly.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Digital Control Box / Control Board
Check Price on Amazon
We may earn a commission from links on this page.