E6
Bradley Smoker Power Supply / Low Voltage Error in Control Board

Digital Bradley smoker intermittently shuts off heating and displays E6.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable mains supply, Loose power cord connection at control box, Failing internal power supply on control board, Corroded spade terminals on main power input

How to Fix / Troubleshooting

Safety first: Unplug the smoker before inspecting the power connections. Do not work on live circuits.

Steps to address E6:

  • Check outlet and extension cords: Plug the smoker directly into a properly grounded outlet. Avoid long or undersized extension cords that can cause voltage drop.
  • Inspect power cord: Examine the Bradley power cord for cuts, kinks, or burn marks. Replace the cord if damaged.
  • Verify cord seating: Ensure the cord is fully inserted into the control box receptacle and that any locking mechanism is engaged.
  • Inspect internal power connections: Remove the control box cover and check the main power input terminals for tightness and corrosion. Clean and tighten as needed.
  • Control board replacement: If power supply issues persist and E6 continues, the internal power supply section of the control board may be failing. Replace the digital control box assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Power Cord / Digital Control Box
Check Price on Amazon

We may earn a commission from links on this page.