Cookshack Intermittent cabinet temperature probe connection

Cabinet temperature reading jumps erratically up and down

Advertisements

Possible Causes

Loose probe wiring at controller, Damaged probe cable where it passes through cabinet, Moisture in probe head, Failing probe element

How to Fix / Troubleshooting

Safety first: Unplug the smoker before accessing wiring.

Steps:

  • 1. Inspect wiring: Check the probe leads at the controller for loose or corroded connections. Reseat connectors.
  • 2. Flex test: Gently wiggle the probe cable while watching the temperature reading (with the smoker ON). If the reading jumps, the cable is likely damaged and the probe should be replaced.
  • 3. Dry the probe: If the smoker was recently washed, allow the probe and cabinet to dry thoroughly.
  • 4. Replace probe: Install a new Cookshack cabinet temperature probe if erratic readings persist.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cookshack cabinet temperature probe
Check Price on Amazon

We may earn a commission from links on this page.