L1
Cuisinart
Low Temperature Lockout or Sensor Calibration Error
Display shows L1 and smoker will not heat above a low temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect sensor calibration in control board, Partially failed temperature sensor, Loose sensor mounting causing false high readings
How to Fix / Troubleshooting
Safety first: Unplug the smoker before accessing internal components.
- Confirm actual temperature: Place a reliable oven thermometer inside the smoker and compare its reading to the display. If the display shows higher than actual, the sensor or calibration is off.
- Check sensor mounting: Ensure the cabinet sensor is firmly attached and not touching the heating element or metal surfaces that could cause it to read hotter than the air.
- Inspect wiring: Tighten any loose sensor connections at the control board.
- Factory reset (if available): Some Cuisinart models allow a factory reset of the controller (consult manual). Perform the reset to clear calibration errors.
- Replace sensor or board: If readings remain inaccurate, replace the cabinet temperature sensor first. If the problem persists, replace the control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor Probe