Dyna-Glo
Premature Cycle Termination
Timer counts down but heating stops before timer reaches zero.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
High‑limit thermostat tripping, Control board logic fault, Intermittent power loss, Door switch intermittently opening
How to Fix / Troubleshooting
Safety first: Unplug and cool the smoker before inspection.
- Monitor power and display: Observe whether the display resets or just the heat stops. A reset suggests power loss; check cord and outlet.
- Check high‑limit thermostat: Replace if it trips at normal cooking temperatures.
- Inspect door switch: Wiggle the door gently during operation; if heat cuts out, adjust or replace the door switch.
- Replace control board: If all hardware is good but the board still stops heating early, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
High-Limit Thermostat
Check Price on Amazon