E11
GE Profile
PID / Temperature Control Calibration Error
Smoker shows E11 and will not maintain set temperature; temperature swings widely.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted control board calibration data, Faulty temperature sensor readings, Control board firmware glitch, Electrical noise on sensor lines
How to Fix / Troubleshooting
Safety first: Unplug the smoker before accessing electronics.
Steps:
- Perform a factory reset of the control system if your GE Profile smoker manual provides a procedure (often involves holding specific buttons while powering on).
- Verify that the cooking chamber temperature sensor is clean and not coated with heavy grease, which can cause delayed or inaccurate readings. Gently clean with a non-abrasive cloth.
- Inspect the sensor wiring for routing near high-voltage lines; if possible, separate sensor wires from heater wires to reduce electrical noise.
- If available, compare the smoker's displayed temperature with an accurate oven thermometer placed inside the chamber. Large discrepancies may indicate a failing sensor.
- Replace the temperature sensor if readings are unstable or far off from actual temperature.
If calibration issues persist, the main control board may need replacement or firmware update by an authorized service provider.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements