E13
GE Profile
Meat Probe Sensor Failure
Smoker shows E13 and meat probe temperature does not register or reads 0°F/– –.
Advertisements
Possible Causes
Damaged meat probe cable, Broken probe tip, Loose probe jack connection, Failed probe input circuit on control board
How to Fix / Troubleshooting
Safety first: Unplug the smoker before working near the control panel.
Probe checks:
- Inspect the GE Profile meat probe for kinks, cuts, or melted insulation along the cable. Replace the probe if any damage is found.
- Ensure the probe is fully inserted into the probe jack on the control panel until it clicks or seats firmly.
- Test the probe with a multimeter by measuring resistance across the plug terminals; compare to expected values (commonly 1–2 kΩ at room temperature). Infinite or erratic readings indicate a bad probe.
- Try a known-good GE-compatible meat probe if available to rule out a control board issue.
If multiple good probes fail to register, the probe input circuit on the control board is likely defective and the board should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Meat Probe Sensor
Check Price on Amazon
We may earn a commission from links on this page.