Klarstein Unresponsive Control Panel

Display works but buttons do not respond or respond intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed touch panel, Loose keypad ribbon cable, Moisture under control overlay, Faulty control board input

How to Fix / Troubleshooting

Safety first: Unplug the smoker.

Steps:

  • Clean and dry: Wipe the control surface and ensure it is completely dry. Avoid using excessive water or cleaners.
  • Reseat ribbon cable: Open the control housing and reseat the keypad or touch panel ribbon cable on the PCB.
  • Check for corrosion: Look for green or white corrosion on connectors; clean with contact cleaner.
  • Replace panel or board: If specific buttons never work, replace the touch panel. If no buttons work and the panel is known good, replace the control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Touch Control Panel
Check Price on Amazon

We may earn a commission from links on this page.