Klarstein
Unresponsive Control Panel
Display works but buttons do not respond or respond intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed touch panel, Loose keypad ribbon cable, Moisture under control overlay, Faulty control board input
How to Fix / Troubleshooting
Safety first: Unplug the smoker.
Steps:
- Clean and dry: Wipe the control surface and ensure it is completely dry. Avoid using excessive water or cleaners.
- Reseat ribbon cable: Open the control housing and reseat the keypad or touch panel ribbon cable on the PCB.
- Check for corrosion: Look for green or white corrosion on connectors; clean with contact cleaner.
- Replace panel or board: If specific buttons never work, replace the touch panel. If no buttons work and the panel is known good, replace the control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Touch Control Panel
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements