E8
Klarstein Low Voltage / Power Supply Error

Display shows E8 and the smoker will not start; sometimes the display flickers or goes blank when pressing START.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty internal power supply on control board, Loose mains power connector, Damaged power cord, Tripped internal fuse on PCB

How to Fix / Troubleshooting

Safety first: Unplug the smoker before any disassembly.

Steps:

  • Check the outlet: Verify the wall outlet has correct voltage using another appliance. Avoid extension cords or power strips that may drop voltage.
  • Inspect power cord: Examine the Klarstein smoker's power cord for cuts, kinks, or burn marks. Replace if damaged.
  • Internal fuse: Remove the rear panel and locate any inline fuse or PCB‑mounted fuse near the power input. Test with a multimeter and replace with the same rating if blown. Investigate for shorts before replacing.
  • Board power section: If fuses and cord are good, the low‑voltage power supply on the control board may be defective. Look for burnt components near the transformer or switching supply. Replace the main control board if faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Power Supply Section / Main Control Board
Check Price on Amazon