F5
Klarstein Element Drive Circuit Fault

Display shows F5 and the smoker fan runs but the heating element never energizes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit between board and element, Blown internal thermal fuse in series with element, Failed element relay on PCB, Loose neutral or live connection to element

How to Fix / Troubleshooting

Safety first: Disconnect power and allow cooling.

Steps:

  • Check continuity from board to element: With the smoker unplugged, disconnect the element wires and test continuity from the control board output terminals to the element connectors. Repair any open wiring.
  • Test thermal fuse: Many Klarstein smokers have a thermal fuse in series with the element wiring. Locate it (often sleeved in fiberglass) and test for continuity. Replace if open.
  • Verify element: Confirm the element itself has proper resistance. If good, suspect the board.
  • Replace control board: If wiring, fuse, and element are good, the element drive circuit on the board is defective and the board must be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermal Fuse / Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.