H1
Klarstein
Temperature Calibration / Sensor Drift High
Display shows H1 and the smoker will not heat above a low temperature; heating cycles are very short.
Advertisements
Possible Causes
Aged or drifted NTC temperature sensor, Poor sensor contact with chamber wall, Grease insulating the sensor, Control board calibration error
How to Fix / Troubleshooting
Safety first: Unplug the smoker and let it cool.
Steps:
- Clean the sensor: Inside the chamber, clean the temperature probe thoroughly to remove grease that can cause false high readings.
- Check mounting: Ensure the sensor is firmly attached to the wall and not hanging loose. Tighten mounting screws if present.
- Compare with external thermometer: Run the smoker at a set temperature and compare with a reliable oven thermometer. If the display reads much higher than actual, the sensor is likely drifted.
- Replace sensor: Swap the temperature sensor probe with a new Klarstein‑specified NTC sensor. Clear any stored error by unplugging for several minutes, then retest.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Temperature Sensor Probe (NTC)
Check Price on Amazon