H2
Klarstein Temperature Calibration / Sensor Drift Low

Display shows H2 and the smoker struggles to reach set temperature; it keeps heating for long periods.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted NTC sensor reading too low, Loose sensor connection causing intermittent readings, Control board calibration fault, Sensor relocated or bent away from heat zone

How to Fix / Troubleshooting

Safety first: Disconnect power and allow cooling.

Steps:

  • Inspect sensor position: Ensure the probe is in its original location and not bent away from the main air stream.
  • Check connector: Reseat the sensor connector on the control board to ensure a solid electrical connection.
  • Test resistance: Measure sensor resistance at room temperature and compare to Klarstein specifications if available. A significantly off‑spec reading indicates a bad sensor.
  • Replace sensor or board: Replace the sensor first. If H2 persists with a new sensor, the control board's calibration circuit may be faulty and the board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Temperature Sensor Probe (NTC)
Check Price on Amazon