E8
Smokehouse Products
Door Switch or Safety Interlock Fault
Display shows E8 and smoker beeps continuously without starting the heating cycle.
Advertisements
Possible Causes
Misaligned door switch actuator, Failed door switch, Broken wiring between door switch and control board
How to Fix / Troubleshooting
Safety first: Unplug the smoker before adjusting the door or switch.
- Check door closure: Ensure the smoker door closes fully and the latch engages. Look for warped door seals or obstructions preventing full closure.
- Inspect door switch: Locate the door switch (usually near the door frame). Confirm the actuator is pressed fully when the door is closed.
- Test switch continuity: Disconnect the switch wires and use a multimeter to test continuity. The switch should show continuity when the door is closed and open when the door is open.
- Adjust or replace switch: If the switch is misaligned, loosen its mounting screws and adjust so the door fully depresses it. If the switch fails continuity tests, replace it with an OEM Smokehouse door switch.
- Inspect wiring: Follow the switch wires to the control board and repair any breaks or loose connectors.
Advertisements
Repair Difficulty
Easy
2/5