E9
Smokehouse Products
Temperature Sensor Calibration or ADC Fault
Display shows E9 and internal temperature reading is obviously incorrect (e.g., shows 300°F when cold).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Drifted temperature sensor, Faulty analog-to-digital converter on control board, Poor sensor ground connection
How to Fix / Troubleshooting
Safety first: Unplug the smoker before accessing internal wiring.
- Compare with external thermometer: Place a reliable oven thermometer inside the smoker and compare readings to the display during operation.
- Inspect sensor mounting: Ensure the sensor tip is not touching the heating element or metal wall directly, which can cause false high readings. It should be exposed to air in the cooking chamber.
- Check sensor wiring and ground: Verify the sensor wires are intact and the ground connection at the control board is tight.
- Replace sensor if readings are offset: If the sensor consistently reads far off from the external thermometer, replace the temperature sensor probe.
- Replace control board if sensor is good: If a new sensor does not correct the error, the control board's ADC or calibration is likely faulty and the board should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Temperature Sensor Probe
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements