Smokin-It Intermittent Temperature Sensor Connection

Controller temperature reading jumps erratically during cook

Advertisements

Possible Causes

Loose sensor connector at control board, Damaged sensor cable insulation, Sensor wire pinched in door or cabinet seam, Corroded sensor terminals

How to Fix / Troubleshooting

Safety first: Unplug the smoker before accessing wiring.

Steps:

  • Inspect sensor cable: Follow the sensor wire from the probe inside the cabinet to the control box. Look for pinch points, cuts, or melted insulation.
  • Reseat connector: Unplug and replug the sensor connector on the control board several times to clean contacts.
  • Secure cable: Use high-temp clips or ties to secure the cable so it does not move or rub during use.
  • Replace sensor: If erratic readings persist, replace the temperature sensor probe assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Temperature Sensor Probe (RTD) Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements