Possible Causes
Loose sensor connector at control board, Damaged sensor cable insulation, Sensor wire pinched in door or cabinet seam, Corroded sensor terminals
How to Fix / Troubleshooting
Safety first: Unplug the smoker before accessing wiring.
Steps:
- Inspect sensor cable: Follow the sensor wire from the probe inside the cabinet to the control box. Look for pinch points, cuts, or melted insulation.
- Reseat connector: Unplug and replug the sensor connector on the control board several times to clean contacts.
- Secure cable: Use high-temp clips or ties to secure the cable so it does not move or rub during use.
- Replace sensor: If erratic readings persist, replace the temperature sensor probe assembly.