Possible Causes

Burned-out high-temp bulb, Loose light socket connections, Failed light switch, Broken light lens allowing moisture in

How to Fix / Troubleshooting

Safety first: Unplug the smoker and ensure the light housing is cool before servicing.

Steps:

  • Check bulb: Remove the light cover and inspect the bulb. Replace with a high-temperature, oven-rated bulb of the same type and wattage.
  • Inspect socket: Look for corrosion or burnt contacts in the socket. Clean or replace the socket if necessary.
  • Test switch: If there is a separate light switch, test for continuity when switched on. Replace if open.
  • Seal lens: Ensure the light lens or cover is intact and properly sealed to keep moisture out.