E004
ABB Contactor / Relay Welded or Stuck

Charger displays E004 and immediately stops or refuses charging; relay click may not be heard.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Main power contactor contacts welded closed, Stuck relay on power board, Mechanical failure of contactor coil or armature, Control board driving signal fault

How to Fix / Troubleshooting

Danger: A welded contactor can leave the output energized unexpectedly. Isolate power at the breaker before any work.

  • Listen for contactor operation: During start-up, you should normally hear a distinct click from the internal main contactor. If E004 appears with no click, the contactor may be stuck or not being driven.
  • Visual inspection: With power off and cover removed, inspect the ABB main contactor for discoloration, melted plastic, or signs of overheating.
  • Manual test (technician): A qualified technician can test coil resistance and manually actuate the contactor (if design allows) to check for mechanical binding.
  • Check control signals: Verify that the control board is sending the correct coil voltage when a charge session is requested. If the board is not driving the coil, the fault may be on the control board.
  • Replace defective part: Replace the main power contactor or relay module with the ABB-specified replacement. If the relay is integrated on the power board, replace the entire power board assembly.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Power Contactor
Check Price on Amazon