E012
ABB Protective Earth (PE) Fault / Ground Integrity Error

Charger shows E012 and refuses to start; often associated with incorrect wiring or missing ground.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Missing or high-resistance earth connection, Loose PE conductor at terminal block, Corroded ground lug, Faulty PE monitoring circuit on control board

How to Fix / Troubleshooting

Safety: A proper earth connection is critical for user safety and RCD operation.

  • Visual check: With power off, verify that the green/yellow earth conductor is securely connected to the ABB charger’s PE terminal and to the building grounding system.
  • Tighten terminals: Tighten the PE terminal screw to the torque specified in the ABB installation manual. Check for corrosion or paint under the ground lug that could increase resistance.
  • Measure earth continuity (electrician): An electrician should measure the resistance between the charger PE terminal and the main grounding point; it should be very low (typically <1 Ω).
  • Check for broken conductor: Inspect the earth conductor along its route for mechanical damage or splices.
  • Control board test: If the earth connection is confirmed good but E012 persists, the PE monitoring circuit on the control board may be faulty and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Protective Earth Terminal / Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements